Study on the Fire Resistance of Concrete-filled Steel Tubular Column to Composite Beam Joints after Earthquake Damage

Author(s): Guo-Qiang Wei, Sun-Hang Ji, Wen-Jing Mao and Wen-Da Wang*

Volume 2, Issue 1, 2022

Published on: 07 September, 2021

Article ID: e051121196209 Pages: 12

DOI: 10.2174/2665998001666210907102634

Price: $65

Open Access Journals Promotions 2
conference banner
Abstract

Background: Post-earthquake fire is one of the secondary disasters caused by the earthquake; many earthquakes around the world have brought about severe fires and led to enormous losses. It is of great significance to study the fire resistance of structures after earthquake to improve the level of urban disaster prevention and reduce the fire loss.

Methods: A nonlinear finite element model of composite joints subjected to post-earthquake fires is established based on ABAQUS software. The state after the earthquake damage is imported into the thermal-stress analysis model through the restart request in ABAQUS, and considered as the initial state of the thermal-stress analysis model.

Results: It is noticed that when the damage index is less than 0.517, the damage level shows significant effect on the fire resistance, but the influence is no longer significant when the damage index reaches 0.781. When only the column is exposed to fire, the column showed obvious local buckling and overall bending deformation. Meanwhile, when the joint area below the concrete slab is exposed to fire, the joint shows a mixed failure mode of the excessive vertical displacement of beam end and column instability.

Conclusion: The fire resistance of the composite joint decreases gradually with the increase of seismic damage level. The fire condition has a significant effect on the fire resistance of the composite joints; with the increase of fire area, the fire resistance of composite joints with same damage degrees decreases gradually.

Keywords: Concrete-filled steel tube, composite beam joint, post-earthquake fire, finite element analysis, damage modes, fire resistance.

Graphical Abstract
[1]
S.W. Chen, and G.Q. Li, "Advance in research on secondary fire of earthquake", J. Natu. Disass., vol. 17, no. 5, pp. 120-126, 2008.
[2]
L.H. Han, Concrete filled steel tubular structures: theory and practice., 3rd ed. Science Press: Beijing, 2016.
[3]
D.S. Wang, and J.L. Zhou, "Development and prospect of hybrid high-rise building structures in China", J. Building Struct., vol. 31, no. 6, pp. 62-70, 2010.
[4]
W.D. Wang, L.H. Han, and J.T. You, "Experimental studies on hysteretic behaviors of steel beam to concrete filled SHS column connections with stiffening ring", China Civil Eng. J., vol. 39, no. 9, pp. 17-26, 2006.
[5]
W. Li, L.F. Xu, and W.W. Qian, "Seismic performance of 3-D steel beam to concrete-encased CFST column joints: Tests", Eng. Mechanics, vol. 232, p. 111793, 2021.
[6]
Y.S. Liu, H. Ma, Z.B. Li, and W.J. Wang, "Seismic behaviour of full-scale prefabricated RC beam-CFST column joints connected by reinforcement coupling sleeves", Structures, vol. 28, pp. 2760-2771, 2020.
[http://dx.doi.org/10.1016/j.istruc.2020.10.066]
[7]
B. Huang, P.Y. Du, and G.Z. Huang, "Quasi-static experimental study of outer diaphragm connections between square concrete filled steel tube columns and steel beams", China Civil Engineering Journal, vol. 45, no. 5, pp. 49-57, 2012.
[8]
D.Y. Ma, L.H. Han, and X.L. Zhao, "Seismic performance of the concrete-encased CFST column to RC beam joint: Experiment", J. Construct. Steel Res., vol. 154, pp. 134-148, 2019.
[http://dx.doi.org/10.1016/j.jcsr.2018.11.030]
[9]
W. Li, "Study on the seismic performance of circular concrete-filled steel tubular column to steel beam joint with external diaphragm", PhD thesis, Tsinghua University, Beijing, China, 2011.
[10]
T.Y. Song, "Research on post-fire performance of steel-concrete composite beam-column joints", PhD thesis, Tsinghua University, Beijing, China, 2010.
[11]
Y.F. Yang, and F. Fu, "Fire resistance of steel beam to square CFST column composite joints using RC slabs: Experiments and numerical studies", Fire Saf. J., vol. 104, pp. 90-108, 2019.
[http://dx.doi.org/10.1016/j.firesaf.2019.01.009]
[12]
J.S. Huo, and L.H. Han, "Hysteretic behaviors of steel beam to concrete-filled steel tubular column connections after exposure to fire", J. Build. Strucs., vol. 27, no. 6, pp. 28-39, 2006.
[13]
Q.H. Tan, L.H. Han, and H.X. Yu, "Fire performance of concrete filled steel tubular (CFST) column to RC beam joints", Fire Saf. J., vol. 54, pp. 68-84, 2012.
[http://dx.doi.org/10.1016/j.firesaf.2012.03.002]
[14]
K. Zhou, and L.H. Han, "Experimental and numerical study of temperature developments of composite joints between concrete-encased concrete-filled steel tube columns and reinforced concrete beams", Fire Saf. J., vol. 116, no. 103187, 2020.
[http://dx.doi.org/10.1016/j.firesaf.2020.103187]
[15]
Q.Y. Song, A. Heidarpour, X.L. Zhao, and L.H. Han, "Post-earthquake fire behavior of welded steel I-beam to hollow column connections: An experimental investigation", Thin-walled Struct., vol. 98, pp. 143-153, 2016.
[http://dx.doi.org/10.1016/j.tws.2015.03.032]
[16]
Q.Y. Song, "Behaviour of steel I-beam to box column connections under post-earthquake fire", PhD thesis, Monash University, Melbourne, Australia, 2015.
[17]
R. Pucinotti, O.S. Bursi, and J.F. Demonceau, "Post-earthquake fire and seismic performance of welded steel-concrete composite beam-to-column joints", J. Construct. Steel Res., vol. 67, no. 9, pp. 1358-1375, 2011.
[http://dx.doi.org/10.1016/j.jcsr.2011.03.006]
[18]
GB50017-2017, “Standard for design of steel structures.”China Building Industry Press: Beijing, .
[19]
GB50936-2014, “Technical code for concrete filled steel tubular structures”China Building Industry Press: Beijing, .
[20]
J.M. Shen, C.Z. Wang, and J.J. Jiang, "Finite element analysis of reinforced concrete and limit analysis of plate and shell.", Tsinghua University Press: Beijing, 1993.
[21]
GB50010-2010, “Code for design of concrete structures”China Building Industry Press: Beijing, .
[22]
T.T. Lie, "Fire resistance of circular steel columns filled with barreinforced concrete", J. Struct. Eng., vol. 120, no. 5, pp. 1489-1509, 1994.
[http://dx.doi.org/10.1061/(ASCE)0733-9445(1994)120:5(1489)]
[23]
ATC-24, "Guidelines for cyclic seismic testing of components of steel structures.", Applied Technology Council: Redwood City, CA, 1992.